UTS1004 is the all makes Unit Injector and Unit Pump Test Bench. Currently more than 1000 units actively being used in 75 different countries, prooving its wide range capability and effectiveness.

 

Features

Adjustable Cam Stroke 

provides testing being as close to as standard working conditions of the injector. Internal pressure level maintains same as when running on the engine, creating a similar condition like in the engine and allowing the delivery to be compatible to the engine conditions. 

 

UTS1004 patented Cam Box design, allows to set the cam stroke without 

  • draining oil,
  • removing cam
  • adjusting timing

It only takes turning a knob a few times to set the cam stroke. 

 

Wide Application Range; from Caterpillar to Continental VDO

UTS1004 has the technical infrastructure to test 

  • Caterpillar EUI: 3406E; C15; C10;C11;C12;C13;C18; 3116 MEUI, 3500 MEUI; 3500E.
  • Cummins: Celect N14/M11/M11+; HPI (ISX and QSK); K-STC;
  • Bosch EUI/EUP all types.
  • Delphi: A0; A3; E1; E3; F2P
  • Detroit Diesel: all types.
  • Continental VDO all types.

 

SRT Measurement

UTS1004 is capable to measure the Solenoid Response Time. SRT value determines the condition of the solenoid, assembly of the control valve with the spring tension and valve stoke. SRT value determines the timing of the delivery and thus relates to many problems such as smoke at accelleration and idling problems.

 

Easy User Interface with Test Plan Create and Calibrate Function

UTS1004 user interface provides all the necessary data on the test screen readily availible for the user to decide the condition of the injector. The software allows the use to create different test plans. Software help user to keep the test plan target values calibrated with its automatic calibration feature. 

UTS1004 EUI & EUP TESTER

Ürün Kodu: UTS1004
  • Dimensions 

     

    Machine Dimensions:

    Width: 1200 mm

    Depth: 800 mm

    Height: 1830 mm

    Weight: 590 kg

     

    Packing Dimensions:

    Width: 1390 mm

    Depth: 1080 mm

    Height: 1970 mm

    Weight: 700 kg

     

    Utilities 

     

    Electricity Requirement

    360-415 Vac 3 phase 50/60 Hz.

    Transformer must be used when local supply is 200-240 3 phase 60 hz.

     

    100- 240 Vac 1 phase 50/60 Hz for electronics and computer.

     

    Air Supply

    Min 5 bar, oil and water free @6L/min flow.

     

     

    Technical Specifications 

     

    Mechanical Equipment

    Main Motor  7.5 kW
    Speed Control AC Drive: 100 to 1200 rpm
    Cam Box Universal Profile, stroke set between 10 and 18 mm.

     

    Test Oil Transfer System

    Tank 30 L
    Pump 4 L/min; gear type
    Supply Pressure 0-25 bar; manually adjusted
    Return Pressure 0-6 bar; manually adjusted
    Test Oil Heater 2kW
    Test Oil Cooler

    Air Cooled, with -5 °C/min with 4L/min transfer; usin

    a seperate transfer pump

     

    Instrumentation

    Flow/Delivery

    Gear Type Flowmeter; max capacity 1000 mm3/str

    digitally displayed as graph mm3/str vs time

    SRT

    ±10µs accuracy with respect to real BIP,

    digitally displayed as graph SRT Value (µs) vs test time

    Inlet Pressure 0-25 bar, digitally displayed

    Return

    Pressure

    0-6 bar, digitally displayed

    Supply

    Temperature

    10-160 °C digitally displayed

    Return

    Temperature

    10-160 °C digitally displayed
bottom of page